Spatial Brain
Spatial Brain XR Lab
- Mixed-reality recordingThe lab running on the headset, filmed in the room.
- Unity shotsThe lab's own panel and the case model, filmed in the Unity editor: the panel's tabs and term list worked through the lab's own controls, and the lab's exploded view.
- Stroke replayThe saved Open Brush strokes drawn again in their recorded order, sped up 6.35 times (split-apart model) and 13.9 times (whole model). Where the pen is shown it follows the recorded stroke points; its movement between strokes was not recorded.
Case 0005 of the ISLES-2022 dataset. The anatomical regions are an automated segmentation. Pulled-apart views are not anatomical positions. The painting was made in standalone Open Brush on the case 0005 models; the film shows a replay of its saved strokes. Methods and limitations
Images and artwork
A scans and expert outline B computed C published maps D the artist's drawing
Hypothesised activation from published meta-analyses. Not measured in this patient.A structure not overlapped by the lesion is not thereby shown to be functionally intact.
ADWI, axial slice through the lesion centroid, with the experts' outline. Case 0005, ISLES-2022.
ADWI, sagittal slice through the lesion centroid, with the experts' outline.
ABCheck sheet: DWI, the FLAIR resampled into the DWI grid, and the SynthSeg labels.
BThe reconstructed model in three views: lesion from the expert mask, regions from SynthSeg.
BPosterior view with labels: where the lesion sits.
ABGrey anatomy with the lesion in red.
CNeurosynth 'fear' association map (363 studies), displayed on the case anatomy.
CNeurosynth 'motor' association map (2,565 studies), displayed on the case anatomy.
BCThe lab's readout for 'reward': the structures that hold part of the lesion come first.
BThe lab and its panel, rendered in Unity.
BCFrom the headset, 11 November 2026: the case beside the reference brain, 'reward' on.
DPainted in Open Brush over the whole-brain model, 26 November 2026. Picture taken in Open Brush.
DThe same painting seen from inside the model. Picture taken in Open Brush.
DThe lesion and the brushwork around it, whole-brain model. Rendered in Unity.
DThe painted split-apart model from above. Rendered in Unity.Pulled apart: not anatomical positions.
DThe lesion and the brushwork around it, split-apart model. Rendered in Unity.Pulled apart: not anatomical positions.
DThe painted split-apart model at giant scale. Rendered in Unity.Pulled apart: not anatomical positions.
Research and documentation
01Research question and hypothesisThe artist's own statement.
Hypothesis. Emotional activation may engage distributed salience, reward and arousal networks that could transiently enhance motor initiation and task performance.
02Scientific evidenceThe artist's own account of the evidence.
In preparation.
03Scientific references35 sources: dataset citations, published papers, software documentation.
35 entries. Each was retrieved from PubMed, Crossref, Zenodo or its own repository on the date shown, and says what it supports here. A reference is a source, not an endorsement of any reading of this case. Entries that name the application support the desktop study application of Spatial Brain, which is not shown on this page.
Dataset citations · 3
The data shown on this page, and the works its publishers ask to be cited.
- Hernandez Petzsche MR, de la Rosa E, Hanning U, Wiest R, Valenzuela W, Reyes M, et al.. ISLES 2022: A multi-center magnetic resonance imaging stroke lesion segmentation dataset. Sci Data. 2022;9(1):762. doi:10.1038/s41597-022-01875-5 · PMID 36496501
- Supports
- A Describes the ISLES-2022 dataset: the DWI, ADC and FLAIR scans and the expert lesion masks, including case sub-strokecase0005.
- Checked
- 2026-11-28: Bibliographic record re-checked in PubMed (NCBI E-utilities). Abstract retrieved and read: 2026-11-11.
- de la Rosa E, Reyes M, Liew SL, Hutton A, Wiest R, Kaesmacher J, et al.. DeepISLES: a clinically validated ischemic stroke segmentation model from the ISLES'22 challenge. Nat Commun. 2025;16(1):7357. doi:10.1038/s41467-025-62373-x · PMID 40783484
- Supports
- A Second work the dataset's Zenodo page asks users to cite (the ISLES'22 challenge). Added on 2026-11-28; it is not yet cited inside the application or on the film's end card.
- Checked
- 2026-11-28: Bibliographic record retrieved from PubMed (NCBI E-utilities). The paper was not read in this project; it is listed because the dataset's page asks for it to be cited.
- Hernandez Petzsche MR, de la Rosa E, Wiest R, Hanning U, Wiestler B, Kirschke JS. ISLES 2022: A multi-center magnetic resonance imaging stroke lesion segmentation dataset. Version 2.3.1. 2022. doi:10.5281/zenodo.7960856
- Supports
- A The data files themselves: Zenodo record 7960856, version 2.3.1, 250 cases. Case sub-strokecase0005 is the one shown.
- Checked
- 2026-11-28: Zenodo record read through the Zenodo API and its page: version, licence and requested citations taken from it.
Published scientific references · 23
Methods
- Yarkoni T, Poldrack RA, Nichols TE, Van Essen DC, Wager TD. Large-scale automated synthesis of human functional neuroimaging data. Nat Methods. 2011;8(8):665-70. doi:10.1038/nmeth.1635 · PMID 21706013
- Supports
- C Neurosynth: the automated meta-analysis that produced the association-test maps used here (reward, fear, motor, arousal, salience, movement, action).
- Checked
- 2026-11-28: Bibliographic record re-checked in PubMed (NCBI E-utilities). Abstract retrieved and read: 2026-11-11.
- Billot B, Greve DN, Puonti O, Thielscher A, Van Leemput K, Fischl B, et al.. SynthSeg: Segmentation of brain MRI scans of any contrast and resolution without retraining. Med Image Anal. 2023;86:102789. doi:10.1016/j.media.2023.102789 · PMID 36857946
- Supports
- B SynthSeg: the segmentation that labels the anatomy of the case (from its FLAIR scan) and of the healthy reference brain.
- Checked
- 2026-11-28: Bibliographic record re-checked in PubMed (NCBI E-utilities). Abstract retrieved and read: 2026-11-11.
- Evans AC, Janke AL, Collins DL, Baillet S. Brain templates and atlases. Neuroimage. 2012;62(2):911-22. doi:10.1016/j.neuroimage.2012.01.024 · PMID 22248580
- Supports
- B Brain templates and atlases: the reference TemplateFlow gives for the MNI152NLin6Asym template, the healthy reference brain in which the maps are sampled.
- Checked
- 2026-11-28: Bibliographic record re-checked in PubMed (NCBI E-utilities). Abstract retrieved and read: 2026-11-11.
- Mitsuhashi N, Fujieda K, Tamura T, Kawamoto S, Takagi T, Okubo K. BodyParts3D: 3D structure database for anatomical concepts. Nucleic Acids Res. 2009;37(Database issue):D782-5. doi:10.1093/nar/gkn613 · PMID 18835852
- Supports
- C BodyParts3D: the scan-derived surfaces inside the NeuroAxis reference atlas.
- Checked
- 2026-11-28: Bibliographic record re-checked in PubMed (NCBI E-utilities). Abstract retrieved and read: 2026-11-11.
- Umeyama S.. Least-squares estimation of transformation parameters between two point patterns. IEEE Transactions on Pattern Analysis and Machine Intelligence. 1991;13(4):376-380. doi:10.1109/34.88573
- Supports
- B The least-squares similarity transform used to place the reference atlas in the case's frame (reference alignment).
- Checked
- 2026-11-28: Crossref record retrieved; details taken from it. The paper itself was not read in this project.
Lesion literature: brainstem
- Kumral E, Bayülkem G, Evyapan D. Clinical spectrum of pontine infarction. Clinical-MRI correlations. J Neurol. 2002;249(12):1659-70. doi:10.1007/s00415-002-0879-x · PMID 12529787
- Supports
- C Application, section 3 (what lesions in a structure typically do): pons, 150 consecutive patients.
- Checked
- 2026-11-28: Bibliographic record re-checked in PubMed (NCBI E-utilities). Abstract retrieved and read: 2026-11-11.
- Bassetti C, Bogousslavsky J, Barth A, Regli F. Isolated infarcts of the pons. Neurology. 1996;46(1):165-75. doi:10.1212/wnl.46.1.165 · PMID 8559368
- Supports
- C Application, section 3 (what lesions in a structure typically do): pons, 36 patients.
- Checked
- 2026-11-28: Bibliographic record re-checked in PubMed (NCBI E-utilities). Abstract retrieved and read: 2026-11-11.
- Kim JS. Pure lateral medullary infarction: clinical-radiological correlation of 130 acute, consecutive patients. Brain. 2003;126(Pt 8):1864-72. doi:10.1093/brain/awg169 · PMID 12805095
- Supports
- C Application, section 3 (what lesions in a structure typically do): lateral medulla, 130 consecutive patients.
- Checked
- 2026-11-28: Bibliographic record re-checked in PubMed (NCBI E-utilities). Abstract retrieved and read: 2026-11-11.
- Kim JS, Han YS. Medial medullary infarction: clinical, imaging, and outcome study in 86 consecutive patients. Stroke. 2009;40(10):3221-5. doi:10.1161/STROKEAHA.109.559864 · PMID 19628797
- Supports
- C Application, section 3 (what lesions in a structure typically do): medial medulla, 86 consecutive patients.
- Checked
- 2026-11-28: Bibliographic record re-checked in PubMed (NCBI E-utilities). Abstract retrieved and read: 2026-11-11.
- Kim JS, Kim J. Pure midbrain infarction: clinical, radiologic, and pathophysiologic findings. Neurology. 2005;64(7):1227-32. doi:10.1212/01.WNL.0000156520.46056.6B · PMID 15824351
- Supports
- C Application, section 3 (what lesions in a structure typically do): midbrain, 40 patients.
- Checked
- 2026-11-28: Bibliographic record re-checked in PubMed (NCBI E-utilities). Abstract retrieved and read: 2026-11-11.
- Parvizi J, Damasio AR. Neuroanatomical correlates of brainstem coma. Brain. 2003;126(Pt 7):1524-36. doi:10.1093/brain/awg166 · PMID 12805123
- Supports
- C Application, section 3 (what lesions in a structure typically do): consciousness, 47 patients with brainstem stroke.
- Checked
- 2026-11-28: Bibliographic record re-checked in PubMed (NCBI E-utilities). Abstract retrieved and read: 2026-11-11.
- Flowers HL, Skoretz SA, Streiner DL, Silver FL, Martino R. MRI-based neuroanatomical predictors of dysphagia after acute ischemic stroke: a systematic review and meta-analysis. Cerebrovasc Dis. 2011;32(1):1-10. doi:10.1159/000324940 · PMID 21576937
- Supports
- C Application, section 3 (what lesions in a structure typically do): swallowing after brainstem and cerebellar stroke; systematic review and meta-analysis, 17 studies, 656 patients.
- Checked
- 2026-11-28: Bibliographic record re-checked in PubMed (NCBI E-utilities). Abstract retrieved and read: 2026-11-11.
Lesion literature: cerebellum
- Edlow JA, Newman-Toker DE, Savitz SI. Diagnosis and initial management of cerebellar infarction. Lancet Neurol. 2008;7(10):951-64. doi:10.1016/S1474-4422(08)70216-3 · PMID 18848314
- Supports
- C Application, section 3 (what lesions in a structure typically do): how cerebellar infarction presents; review.
- Checked
- 2026-11-28: Bibliographic record re-checked in PubMed (NCBI E-utilities). Abstract retrieved and read: 2026-11-11.
- Schmahmann JD, Macmore J, Vangel M. Cerebellar stroke without motor deficit: clinical evidence for motor and non-motor domains within the human cerebellum. Neuroscience. 2009;162(3):852-61. doi:10.1016/j.neuroscience.2009.06.023 · PMID 19531371
- Supports
- C Application, section 3 (what lesions in a structure typically do): movement after cerebellar stroke, 39 patients.
- Checked
- 2026-11-28: Bibliographic record re-checked in PubMed (NCBI E-utilities). Abstract retrieved and read: 2026-11-11.
- Stoodley CJ, MacMore JP, Makris N, Sherman JC, Schmahmann JD. Location of lesion determines motor vs. cognitive consequences in patients with cerebellar stroke. Neuroimage Clin. 2016;12:765-775. doi:10.1016/j.nicl.2016.10.013 · PMID 27812503
- Supports
- C Application, section 3 (what lesions in a structure typically do): motor and cognitive consequences by lesion location, 18 patients.
- Checked
- 2026-11-28: Bibliographic record re-checked in PubMed (NCBI E-utilities). Abstract retrieved and read: 2026-11-11.
- Schoch B, Dimitrova A, Gizewski ER, Timmann D. Functional localization in the human cerebellum based on voxelwise statistical analysis: a study of 90 patients. Neuroimage. 2006;30(1):36-51. doi:10.1016/j.neuroimage.2005.09.018 · PMID 16253526
- Supports
- C Application, section 3 (what lesions in a structure typically do): which part of the cerebellum goes with which movement, 90 patients.
- Checked
- 2026-11-28: Bibliographic record re-checked in PubMed (NCBI E-utilities). Abstract retrieved and read: 2026-11-11.
- Timmann D, Brandauer B, Hermsdörfer J, Ilg W, Konczak J, Gerwig M, et al.. Lesion-symptom mapping of the human cerebellum. Cerebellum. 2008;7(4):602-6. doi:10.1007/s12311-008-0066-4 · PMID 18949530
- Supports
- C Application, section 3 (what lesions in a structure typically do): lesion-symptom mapping by zone; review.
- Checked
- 2026-11-28: Bibliographic record re-checked in PubMed (NCBI E-utilities). Abstract retrieved and read: 2026-11-11.
- Schmahmann JD, Sherman JC. The cerebellar cognitive affective syndrome. Brain. 1998;121 ( Pt 4):561-79. doi:10.1093/brain/121.4.561 · PMID 9577385
- Supports
- C Application, section 3 (what lesions in a structure typically do): the cerebellar cognitive affective syndrome, 20 patients.
- Checked
- 2026-11-28: Bibliographic record re-checked in PubMed (NCBI E-utilities). Abstract retrieved and read: 2026-11-11.
Brainstem nuclei table
- Mobbs D, Petrovic P, Marchant JL, Hassabis D, Weiskopf N, Seymour B, et al.. When fear is near: threat imminence elicits prefrontal-periaqueductal gray shifts in humans. Science. 2007;317(5841):1079-83. doi:10.1126/science.1144298 · PMID 17717184
- Supports
- C Brainstem nuclei table (application section 5; lab Activation tab): periaqueductal grey and fear; human fMRI; confidence high.
- Checked
- 2026-11-28: Bibliographic record re-checked in PubMed (NCBI E-utilities). Abstract retrieved and read: 2026-11-08.
- Liu Z, Zhou J, Li Y, Hu F, Lu Y, Ma M, et al.. Dorsal raphe neurons signal reward through 5-HT and glutamate. Neuron. 2014;81(6):1360-1374. doi:10.1016/j.neuron.2014.02.010 · PMID 24656254
- Supports
- C Brainstem nuclei table (application section 5; lab Activation tab): dorsal raphe and reward; mouse study; confidence medium.
- Checked
- 2026-11-28: Bibliographic record re-checked in PubMed (NCBI E-utilities). Abstract retrieved and read: 2026-11-08.
- Samuels ER, Szabadi E. Functional neuroanatomy of the noradrenergic locus coeruleus: its roles in the regulation of arousal and autonomic function part I: principles of functional organisation. Curr Neuropharmacol. 2008;6(3):235-53. doi:10.2174/157015908785777229 · PMID 19506723
- Supports
- C Brainstem nuclei table (application section 5; lab Activation tab): locus coeruleus and arousal; review, mainly animal data; confidence high.
- Checked
- 2026-11-28: Bibliographic record re-checked in PubMed (NCBI E-utilities). Abstract retrieved and read: 2026-11-08.
- Benarroch EE. Pain-autonomic interactions. Neurol Sci. 2006;27 Suppl 2:S130-3. doi:10.1007/s10072-006-0587-x · PMID 16688616
- Supports
- C Brainstem nuclei table (application section 5; lab Activation tab): nucleus of the solitary tract and arousal; review; confidence low.
- Checked
- 2026-11-28: Bibliographic record re-checked in PubMed (NCBI E-utilities). Abstract retrieved and read: 2026-11-08.
- Bandler R, Shipley MT. Columnar organization in the midbrain periaqueductal gray: modules for emotional expression?. Trends Neurosci. 1994;17(9):379-89. doi:10.1016/0166-2236(94)90047-7 · PMID 7817403
- Supports
- C Brainstem nuclei table (application section 5; lab Activation tab): periaqueductal grey, emotion and motor responses; review of animal data; confidence medium.
- Checked
- 2026-11-28: Bibliographic record re-checked in PubMed (NCBI E-utilities). Abstract retrieved and read: 2026-11-08.
Data sources and software documentation · 9
Websites, repositories and programs. These are not peer-reviewed publications.
- Neurosynth. Neurosynth: term-based meta-analysis maps and FAQ. neurosynth.org
- Supports
- C Where the seven association-test maps were downloaded (2026-11-08; image numbers and file hashes are in the provenance record) and where the map type is defined (FAQ).
- Checked
- 2026-11-28: FAQ page fetched and read on the date shown; the map downloads are recorded in the atlas repo's data/reference/neurosynth/provenance.json.
- Neurosynth. neurosynth-data: Neurosynth database files. github.com/neurosynth/neurosynth-data
- Supports
- C States the licence of the Neurosynth database (Open Database License 1.0).
- Checked
- 2026-11-28: Repository README and licence file fetched and read.
- Billot B, et al.. SynthSeg (code and the synthseg_1.0 model). Version 1.0. github.com/BBillot/SynthSeg
- Supports
- B The program that was run: repository checkout 2a2aa3b of 2024-07-17, model synthseg_1.0.h5, on Python 3.12 with TensorFlow 2.18.1 through the project's tools/synthseg_setup.py.
- Checked
- 2026-11-28: Repository README and licence file fetched and read; the checkout's commit read from the local clone.
- TemplateFlow (template authors: Janke AL). MNI152NLin6Asym: FSL's MNI ICBM 152 non-linear 6th Generation Asymmetric Average Brain Stereotaxic Registration Model. www.templateflow.org
- Supports
- B The healthy reference brain (1 mm T1-weighted template) in which the Neurosynth maps are sampled per structure.
- Checked
- 2026-11-28: The template's description file fetched and read. It names no licence text (see the licence register).
- NeuroAxis contributors. NeuroAxis: 3D Brainstem Atlas. github.com/linkbag/neuroaxis-atlas
- Supports
- C The reference atlas shown as the faint second brain and for structures the case's own segmentation cannot resolve. Commit e57569bc of 2026-10-05, exported to NeuroAxisBrain.glb on 2026-10-24.
- Checked
- 2026-11-28: Repository licence and attribution document fetched and read; the commit is recorded in NeuroAxisBrain_ATTRIBUTION.md.
- The Database Center for Life Science (DBCLS). BodyParts3D 4.0. Version 4.0. dbarchive.biosciencedbc.jp/en/bodyparts3d/download.html
- Supports
- C The anatomical surface database from which the NeuroAxis atlas derives its scan-based surfaces.
- Checked
- 2026-11-28: Licence page of the database fetched and read.
- Icosa Foundation and Open Brush contributors. Open Brush. Version 2.32 (lab), 2.31 (artwork). github.com/icosa-foundation/open-brush
- Supports
- The VR painting program. The XR lab is a modified copy of version 2.32; the artwork was painted in standalone Open Brush 2.31.
- Checked
- 2026-11-28: Repository licence and README fetched and read.
- three.js authors. three.js. Version r170. threejs.org
- Supports
- Draws the 3D model in the browser application. Revision 170, shipped with the application.
- Checked
- 2026-11-28: Licence fetched from the repository; the shipped copy carries its own licence file and revision number.
- The Khronos Group and contributors. UnityGLTF. github.com/KhronosGroup/UnityGLTF
- Supports
- Imports the case models into the XR lab.
- Checked
- 2026-11-28: Licence fetched from the repository.
04Dataset and computational provenanceWhere every picture comes from, in ten steps, from scan to film.
Four kinds of material
- A Original clinical imaging and expert annotations
- B Computationally derived anatomical representations
- C Published functional reference maps and interpretive comparisons
- D The artist's own annotations and interpretations
Three things that are not the same
- Anatomical overlap: the share of the lesion that lies in a structure, and the share of that structure the lesion covers. Computed in this case (tier B).
- Statistical association: how consistently published studies that use a term report activation in a structure of a healthy reference brain. Published data, sampled per structure (tier C source, tier B computation).
- Patient-specific functional activity: not available. No functional scan of this patient exists in the dataset. Any relation between the reference maps and this patient is labelled hypothesised.
The pipeline for case 0005
- 1
Imaging dataset and case A
- ISLES-2022, a public multi-centre MRI dataset of 250 acute and sub-acute ischaemic stroke cases, Zenodo record 7960856, version 2.3.1.
- The case shown is sub-strokecase0005. Extracted from ISLES-2022.zip; the data files are not changed and are not redistributed by this project.
Sources: Hernandez Petzsche et al. 2022, de la Rosa et al. 2025, ISLES 2022
Read from: atlas repo: data/ATTRIBUTION.md; records/evidence/2026-11-28/zenodo_7960856.txt
- 2
Source scans and expert lesion annotation A
- Three MRI series as supplied: DWI (b = 1000), ADC and FLAIR, skull-stripped, in the scanner's own space. DWI, ADC and the mask share a 2 mm grid; the FLAIR has its own, finer grid.
- The lesion mask was drawn by the dataset's experts, in the DWI grid.
- Scanner, from the dataset's metadata file for this case: Philips Achieva dStream, 3 T.
- The dataset holds no clinical data for the case: no symptoms, no outcome, no vascular imaging.
Sources: Hernandez Petzsche et al. 2022
Read from: atlas repo: exports/sub-strokecase0005/build.json (scanner_A, provenance.A); atlas repo: README, section Data
Not yet verifiedWhether the dataset's conversion from the scanner format mirrored any image at voxel level cannot be excluded from the file headers alone (the headers agree with the scanner's record to 0.0 degrees).
- 3
Automated anatomical segmentation B
- SynthSeg 1.0 was run on the FLAIR scan and gives one label per voxel: 31 structures with a mesh in this case.
- Program: SynthSeg repository checkout 2a2aa3b (2024-07-17), model synthseg_1.0.h5, run on Python 3.12 with TensorFlow 2.18.1 after the project's own compatibility patch (tools/synthseg_setup.py).
- The brainstem is one label (no midbrain, pons or medulla); each side's cerebellar cortex is one label; cerebrospinal fluid is not labelled.
- SynthSeg's own quality-control model was not available, so no automated quality score exists for this segmentation.
Sources: Billot et al. 2023, SynthSeg (code and the synthseg_1.0 model)
Read from: atlas repo: README, sections SynthSeg and Ranking; atlas repo: data/cache/scores/sub-strokecase0005.json (synthseg_qc_note); local clone tools/SynthSeg (commit)
Not yet verifiedThe effect of the compatibility patch on SynthSeg's output was not compared against an unpatched run.
- 4
Registration and spatial alignment B
- The case's images are not registered to a standard space (MNI). Nothing in the pipeline warps the patient's images.
- The FLAIR and the SynthSeg labels are resampled into the lesion-mask grid through the files' own affines (trilinear for the FLAIR, nearest neighbour for labels). No optimised registration between the FLAIR and DWI series is run.
- Check of that step for this case: overlap (Dice) of the resampled FLAIR brain mask with the DWI brain mask 0.981; below 0.85 a case is flagged.
- The reference atlas (NeuroAxis) is placed in the case's frame by a similarity transform (rotation, one scale, translation) fitted by least squares on the centroids of 18 of the 23 structures both share: scale 0.883, rotation 9.4 degrees, RMS residual 5.0 mm (fitted 2026-11-11). It is a structure-level fit, not a voxel-level registration.
Sources: Umeyama 1991
Read from: atlas repo: README, sections Coordinates and Reference alignment; atlas repo: exports/sub-strokecase0005/build.json (measurements_B.flair_alignment, reference_alignment.neuroaxis); atlas repo: stroke_atlas/alignment.py
- 5
Conversion into 3D anatomical models B
- One surface per SynthSeg label (31) and one for the lesion. Each surface is extracted from its label volume with marching cubes (scikit-image), smoothed (Taubin; 8 passes for regions, 12 for the lesion, whose mask is first doubled in resolution and lightly blurred) and reduced in triangle count (fast-simplification). 297,614 triangles in all; the lesion mesh has 8,442.
- One fixed transform for every vertex: scanner millimetres (RAS) minus the brain's bounding-box centre, turned into model metres. It is a rotation (determinant +1), never a mirror.
- Two files with the same geometry: one in colour, one in grey. The lesion is always red. Built on 2026-11-11.
- Left and right were checked three ways: in the file headers against the scanner's record; numerically (the browser viewer and the headset import place all 147,003 vertices identically); and on the headset on 2026-11-07.
Read from: atlas repo: stroke_atlas/build.py, stroke_atlas/transform.py; atlas repo: exports/sub-strokecase0005/build.json (meshes, triangles_total, transform, left_right_verification); atlas repo: tests/test_viewer_matches_unity.py
Not yet verifiedThe smoothing changes the surfaces slightly: the lesion mesh encloses 5.18 ml against 5.82 ml in the mask. No tolerance for this has been set or reviewed.
- 6
Functional reference-map sources C
- Seven Neurosynth association-test maps, downloaded from neurosynth.org on 2026-11-08: reward (image 182, 922 studies), fear (2266, 363), motor (2558, 2,565), arousal (3582, 295), salience (4926, 396), movement (4214, 670), action (2942, 886). Address, size and SHA-256 of each file are recorded.
- An association-test map holds z-scores for whether studies that use the term report activation at a voxel more consistently than studies that do not. As downloaded, the maps are thresholded (FDR 0.01): voxels below threshold are 0.
- The maps are in MNI152 space at 2 mm. The 'salience' map has only 26 voxels above threshold in the whole brain.
- Neurosynth has no analysis for 'emotion', 'love' or 'awe'; nothing was substituted for them.
Sources: Yarkoni et al. 2011, Neurosynth, neurosynth-data
Read from: atlas repo: docs/activation.md; atlas repo: data/reference/neurosynth/provenance.json; records/evidence/2026-11-28/page_neurosynth_faq.txt
Not yet verifiedWhich version of the Neurosynth database the website's maps come from: neurosynth.org does not state it.
- 7
Structure-level map sampling and anatomical overlap B
- Reference side: the same SynthSeg 1.0 model labels the healthy template brain (MNI152NLin6Asym, 1 mm). The labels are resampled onto each map's 2 mm grid, and for every structure the mean z, the 90th percentile and the share of voxels above threshold (positive and negative) are recorded.
- Case side: for every structure, the share of the lesion that lies in it and the share of the structure the lesion covers, from the expert mask and the case's labels. For case 0005: brainstem 64.2 % of the lesion (16.0 % of the structure), right cerebellar cortex 25.3 % (2.8 %), left cerebellar cortex 4.4 % (0.5 %).
- The two sides are joined by structure name only. A value shown on the patient's anatomy is a reference value for a structure of that name in a healthy template, displayed there.
- Each structure carries a mapping confidence (high, medium, low) by its size and tissue type; white matter and ventricles are low.
Sources: Yarkoni et al. 2011, Billot et al. 2023, Evans et al. 2012, MNI152NLin6Asym
Read from: atlas repo: stroke_atlas/activation.py, docs/activation.md; atlas repo: exports/sub-strokecase0005/activation_overlap.json; atlas repo: exports/reference/activation/
Not yet verifiedThe licence of the template brain (see the licence register).
- 8
Import into Unity and the XR laboratory B
- The XR lab is a modified copy of Open Brush 2.32, built with Unity 2022.3.62f3 for Meta Quest 3.
- It loads the same model files and the same record files as the desktop application, through Open Brush's own model import (UnityGLTF). The import flips the X axis, which the lab accounts for; orientation was verified on the headset on 2026-11-07.
- In the lab the map values tint the anatomy by the positive share only; structures with a mainly negative association are listed apart and are not lit. The lesion is never tinted.
- The two caution sentences are fixed on the lab's Activation tab and above each tinted brain.
Sources: Open Brush, UnityGLTF
Read from: lab repo: HOW-THE-LAB-WORKS.md; lab repo: Docs/stroke-panel-log.md; atlas repo: README, section Coordinates
- 9
Open Brush artwork and annotation D
- Painted by Vaidehi Bhargava on 26 November 2026 in standalone Open Brush 2.31 on a Meta Quest 3, over two models of case 0005 in the 'reward' look: the whole brain and a split-apart copy.
- One sketch, 74 strokes: 42 on the whole model (6 min 22 s from first to last stroke), 31 on the split-apart model (1 min 54 s), and one stray dab.
- The split-apart model is the same anatomy with the pieces moved outward: pulled apart, not anatomical positions.
- The strokes are not aligned to the anatomy by any computation and are filed unchanged. They were not painted inside the XR lab build.
Sources: Open Brush
Read from: sketch Untitled_270.tilt (stroke data and timestamps); atlas repo: HOW-TO-ANNOTATE.md; lab repo: Builds/film/explainer/footage/footage.md
- 10
Unity recreation and film D
- The film holds three kinds of picture. Mixed-reality recordings: the lab running on the headset, filmed in the room. Unity shots: the lab's own panel and the case model filmed in the Unity editor, the panel's tabs and term list worked through the lab's own controls, and the lab's exploded view. Stroke replays: the saved strokes of the sketch drawn again in their recorded order by Open Brush's own playback.
- The stroke replays are sped up 6.35 times (split-apart model, with the pen) and 13.9 times (whole model, no pen). Where the pen is shown it follows the recorded stroke points; its movement between strokes was not recorded and is filled in. No hands are drawn.
- The painting was made in standalone Open Brush on the case 0005 models; the film shows a replay of its saved strokes.
- Cut shown: the fourth cut of 28 November 2026, 1 min 32 s (86 s of film and a 6 s end card), silent.
Read from: lab repo: Builds/film/explainer/sixty/SpatialBrain_cut4_cut-list.md; lab repo: Builds/film/explainer/sixty/SpatialBrain_cut4_notes.md; lab repo: Builds/film/explainer/footage/footage.md
Not yet verifiedNo independent viewer has checked the film against its sources. Its pacing and joins were checked only by its maker, on frames.
05Methods and limitationsWhat this material is not, stated plainly.
Reference maps
- The Neurosynth maps are not measurements of activity in case 0005. They are meta-analytic association maps from published studies, sampled in a healthy template brain. No functional scan of this patient exists in the dataset.atlas repo: docs/activation.md
- A map value is a z-score for the association between a word in study abstracts and reported activation. It describes a body of published studies, not a measured response and not one person.Neurosynth FAQ (records/evidence/2026-11-28/page_neurosynth_faq.txt)
- Structural non-overlap does not establish preserved function. Nothing in this project tests function in any structure.the second fixed sentence; atlas repo: docs/activation.md
- The case is not registered to the template. Lesion and map values are joined by structure name only, so a value is known per whole structure, not per location inside it.atlas repo: docs/activation.md; activation_overlap.json (registration)
- The 'salience' map has 26 voxels above threshold in the whole brain, so almost every structure reads 0. Neurosynth has no map for 'emotion'.atlas repo: docs/activation.md
Anatomy
- The anatomical regions are an automated estimate (SynthSeg 1.0 on a clinical FLAIR scan), not validated anatomy. No automated quality score was available for it.atlas repo: README; data/cache/scores (synthseg_qc_note)
- The brainstem is one label. The records cannot place the lesion in the midbrain, pons or medulla, or in any nucleus; the cerebellar cortex of each side is likewise one label.atlas repo: README, sections Ranking and Study page
- The FLAIR-derived labels reach the lesion's grid by resampling through the files' own affines, without an optimised registration. Movement between the two scans is not corrected (overlap check for this case: 0.981).atlas repo: README, section Coordinates; build.json
- The reference atlas is a different, partly schematic brain placed by a structure-level fit (RMS 5.0 mm). A reference structure does not sit where that structure is in the patient. Its deep nuclei are hand-modelled teaching shapes.build.json (reference_alignment); NeuroAxisBrain_ATTRIBUTION.md
- Left and right were verified in the file headers, numerically and on the headset. A voxel-level mirror inside the dataset's own file conversion cannot be excluded from headers alone.build.json (left_right_verification)
- The dataset holds no clinical information for the case. Nothing here states what this patient experienced, and no vascular territory is inferred from the lesion.atlas repo: README, section Provenance
Display
- Exploded and split-apart views are not anatomical positions. The pieces are moved outward so they can be seen; the lesion is not moved.lab repo: HOW-THE-LAB-WORKS.md; atlas repo: stroke_atlas/openbrush.py
- Colours are a display choice. The lesion's red marks where the expert mask is, not how severe the damage is. A map's tint follows the published reference value for a structure, not anything measured in the patient.atlas repo: README (palette); lab repo: HOW-THE-LAB-WORKS.md
Artwork
- The painted strokes are the artist's annotations. They are not measured neural activity and not verified anatomical pathways, and they are not aligned to the anatomy by any computation.atlas repo: HOW-TO-ANNOTATE.md; film brief of 2026-11-27
Film
- The film mixes real mixed-reality recordings with shots filmed in the Unity editor. The painting sequences are replays of saved strokes, sped up 6.35 and 13.9 times; the pen's movement between strokes was not recorded.lab repo: Builds/film/explainer/sixty/SpatialBrain_cut4_cut-list.md, footage.md
Review
- AI-assisted. Independent scientific and clinical review is pending. The literature summaries inside the desktop study application are paraphrases of published abstracts and have not been checked by a specialist.film credits; atlas repo: README, section Study page
06Software and licensing acknowledgementsSources, licences, required attributions, and what is still unverified.
20 items: 11 verified at their source, 6 partly, 0 not yet verified, 3 the artist's own work. Licensing has not been cleared as a whole: the items marked below must be settled first.
Scientific data
ISLES-2022 imaging data and expert lesion masks (case sub-strokecase0005)
verified- Source
- Hernandez Petzsche MR, de la Rosa E, et al.; ISLES'22 organisers; hosted on Zenodo · source
- Publication
- Hernandez Petzsche et al., Sci Data 2022; de la Rosa et al., Nat Commun 2025
- Licence
- CC BY 4.0
- Attribution
- Cite both works the Zenodo page names (Hernandez Petzsche et al. 2022; de la Rosa et al. 2025), name the licence, and say that changes were made.
- Changed
- Yes. Shown only as derived material: surface models made from the mask and from software labels of the FLAIR, DWI slices with the expert outline drawn on them (two in the gallery), and measurements. The original image files are not redistributed.
- Used in
- application; XR lab; film; gallery
- Notes
- Attribution and a statement of changes are required. The film's end card and the application's source list cite the 2022 paper only; the 2025 paper was added to the Zenodo page's request later.
- Checked
- 2026-11-28
Neurosynth association-test maps: reward, fear, motor, arousal, salience, movement, action
partly verified- Source
- Yarkoni T, et al.; neurosynth.org · source
- Publication
- Yarkoni et al., Nat Methods 2011
- Licence
- The Neurosynth database is released under the Open Database License (ODbL) 1.0. neurosynth.org states no licence for the map images it serves.
- Attribution
- Cite Yarkoni et al. 2011. Under the ODbL: attribute any public use, share any derivative database under the same licence, keep derivative data open.
- Changed
- Yes. The map files are not redistributed. They were sampled per anatomical structure (mean z, 90th percentile, share above threshold) and those values are shown as tables and as a tint on the anatomy.
- Used in
- application; XR lab; film; gallery
- Notes
- NOT CONFIRMED: whether the images served by neurosynth.org fall under the database's ODbL, and whether a per-structure table of values counts as a 'derivative database' that must itself be offered under the ODbL. Ask the Neurosynth maintainers or take advice before publication.
- Checked
- 2026-11-28
MNI152NLin6Asym template brain (TemplateFlow copy), 1 mm T1-weighted
partly verified- Source
- TemplateFlow; template authors as listed there (Janke AL); FSL's version of the MNI ICBM 152 non-linear 6th generation model · source
- Publication
- Evans et al., NeuroImage 2012
- Licence
- No licence file exists in TemplateFlow's repository for this template, although its description says 'See LICENSE file'. The Montreal Neurological Institute's own page for the 6th generation model carries a permissive notice: copyright 1993-2009 Louis Collins, McConnell Brain Imaging Centre, Montreal Neurological Institute, McGill University; use, copying, modification and distribution for any purpose without fee, provided the copyright notice appears in all copies.
- Attribution
- Cite Evans et al. 2012 (the reference the description file gives). The MNI notice asks for its copyright line in all copies.
- Changed
- Not shown and not redistributed. The template was labelled with SynthSeg and used only to sample the maps per structure.
- Used in
- pipeline only
- Notes
- NOT CONFIRMED: which terms cover the exact file used. The MNI page is for the symmetric model; TemplateFlow's file is FSL's asymmetric version. FSL's licence page (a non-commercial software licence) does not mention the MNI152 templates. It affects the pipeline, not what is displayed.
- Checked
- 2026-11-28
NeuroAxis 3D Brainstem Atlas (NeuroAxisBrain.glb, 273 meshes)
verified- Source
- NeuroAxis contributors · source
- Publication
- github.com/linkbag/neuroaxis-atlas, commit e57569bc (2026-10-05)
- Licence
- MIT (original geometry: sculpted nuclei, tracts, nerves, vessels)
- Attribution
- Keep the notice 'Copyright (c) 2026 NeuroAxis contributors' and the MIT permission notice with every copy of the model. The attribution file NeuroAxisBrain_ATTRIBUTION.md travels with the model file.
- Changed
- Yes. File-format conversion, re-centring, scaling to life size in metres, the project's own display colours; placed in the case's frame by a fitted similarity transform. No remodelling.
- Used in
- desktop study application (reference brain); XR lab; film
- Notes
- Its sculpted nuclei are schematic teaching shapes and its tracts, nerves and vessels are drawn centre-lines: they must not be presented as validated anatomy (upstream's own statement).
- Checked
- 2026-11-28
BodyParts3D 4.0 surfaces inside the NeuroAxis atlas (66 meshes)
verified- Source
- The Database Center for Life Science (DBCLS) · source
- Publication
- Mitsuhashi et al., Nucleic Acids Res 2009
- Licence
- CC BY 4.0
- Attribution
- Verbatim: "BodyParts3D, © The Database Center for Life Science licensed under CC Attribution 4.0 International".
- Changed
- Yes. By NeuroAxis: axis and unit conversion, registration, resampling and sculpting, a modelled cortical ribbon. By this project: format conversion, re-centring, scaling, colours.
- Used in
- application (reference brain); XR lab; film
- Notes
- Attribution with the exact sentence; changes must be stated.
- Checked
- 2026-11-28
Software
SynthSeg 1.0 (code and model)
verified- Source
- Billot B, et al. · source
- Publication
- Billot et al., Med Image Anal 2023
- Licence
- Apache License 2.0
- Attribution
- Cite Billot et al. 2023 (the repository's own request for the non-robust version).
- Changed
- The program was patched locally to run on Python 3.12 (imports only). Its output, the label maps, is derived from the ISLES data.
- Used in
- pipeline only
- Notes
- The program is not redistributed.
- Checked
- 2026-11-28
Open Brush (the XR lab's base, version 2.32; the artwork's tool, version 2.31), including its brushes
partly verified- Source
- Icosa Foundation and Open Brush contributors; derived from Tilt Brush by Google · source
- Publication
- github.com/icosa-foundation/open-brush
- Licence
- Apache License 2.0
- Attribution
- Credit Open Brush; if the lab's program is ever distributed, keep the licence and notices and mark changed files.
- Changed
- Yes. The XR lab adds the reference brain, the stroke case panel, hand and pen input and a spectator stream to version 2.32. The brushes are used as shipped.
- Used in
- XR lab; artwork; film; gallery
- Notes
- 'Tilt Brush' is a Google trademark and must not be used as the name of a derived app. Seven gallery pictures carry the Open Brush logo that the program stamps on its snapshots: whether the logo may appear in published pictures was NOT checked. No separate licence for the brush shaders and textures was found in the repository; they were taken to be covered by the repository licence, which was NOT confirmed with the maintainers.
- Checked
- 2026-11-28
three.js r170
verifiedUnityGLTF (model import in the lab)
verifiedPython libraries of the pipeline: nibabel, NumPy, SciPy, scikit-image, trimesh, fast-simplification, Pillow, Flask
partly verified- Source
- their respective authors
- Licence
- MIT (trimesh, fast-simplification); BSD 3-Clause (SciPy, Flask, scikit-image's own code); NumPy, nibabel and Pillow: see their licence files
- Attribution
- None for display.
- Changed
- No.
- Used in
- pipeline only
- Notes
- Not redistributed. For NumPy, nibabel and Pillow the licence files were fetched but the licence type was not classified here.
- Checked
- 2026-11-28
Unity Editor and engine 2022.3.62f3
verified- Source
- Unity Technologies · source
- Licence
- Unity Terms of Service and Unity Editor Software Terms (both last updated 16 November 2026)
- Attribution
- None stated in the terms read.
- Changed
- No.
- Used in
- XR lab; film (rendering)
- Notes
- The Terms of Service say your content is yours (section 6). Unity Personal may be used only while your total finances of the last twelve months are at most US$200,000. Customers who develop projects for healthcare can count as 'Industry Customers', with a US$1,000,000 threshold above which only Unity Industry may be used; Unity decides who qualifies. Which Unity plan this project uses was not established.
- Checked
- 2026-11-28
Meta XR Core SDK 68.0.2 and Oculus XR plugin 4.5.1 (headset support in the lab)
verified- Source
- Meta Platform Technologies, LLC; Unity Technologies (the plugin) · source
- Licence
- Meta Platform Technologies SDK License Agreement (effective 25 October 2022), named in the licence file of the SDK version in use. The Oculus XR plugin: Unity Companion License and Unity Package Distribution License, as its own licence file states (those two texts were not read).
- Attribution
- None for display. Redistributed sample material must carry Meta's copyright notice.
- Changed
- The lab inherits Open Brush's own patched copy of the SDK package (68.0.2-openbrush-hotfix.2).
- Used in
- XR lab
- Notes
- The licence allows the SDK to be used only to develop, test and promote applications for Meta-approved devices. Its section 1.7 says the SDK is not intended to be a medical device unless Meta says otherwise in writing. Not redistributed by the page.
- Checked
- 2026-11-28
Visual assets
The lab panel's look: two sprites (UIPanel.png, UIButtonDefault.png) and the typeface Jupiter.ttf, from the Asset Store pack 'UI Examples | uGUI Sample Project' (in the project as 'Unity UI Samples')
verified- Source
- Unity Technologies (sprites); Isurus Labs (typeface) · source
- Publication
- Unity Asset Store package 25468, free
- Licence
- Sprites: Standard Unity Asset Store EULA (Asset Store Terms last updated 4 December 2024), licence type 'Extension Asset'. Typeface: public domain, according to the LICENSE.txt shipped beside it in the pack.
- Attribution
- None required by the terms read.
- Changed
- Used as shipped, inside the lab's panel.
- Used in
- film; gallery (wherever the panel is in the picture)
- Notes
- EULA section 2.2.1 licenses an asset to be built into an application or digital media, together with substantial original content, and to be publicly displayed as built in. The sprite files must not be passed on by themselves (2.2.1.1), and an Extension Asset may be installed on at most two computers (2.3.2). Unity was not asked whether pictures and film of the panel count as display 'as incorporated'; that is how the clause reads.
- Checked
- 2026-11-28
Logitech MX Ink pen model (logitech_vr_stylus_v1.0.fbx; seen in the film's stroke-replay shots)
partly verified- Source
- Logitech · source
- Publication
- Logitech's MX Ink developer resources; added to Open Brush by pull request 768 (merged 6 October 2024)
- Licence
- No licence text found. Logitech's developer page offers the 3D model to developers and says it can be used to represent MX Ink in an app.
- Attribution
- Not determined.
- Changed
- Shape unchanged. In the film it is drawn in front of the see-through anatomy so that it stays visible.
- Used in
- film
- Notes
- NOT CONFIRMED: the terms for showing the model in published film and pictures. No licence file sits in its folder in Open Brush; the MIT file in the neighbouring LogiPen folder belongs to a different, older Logitech pen. The repository behind Logitech's developer page is not public. 'MX Ink' and 'Logitech' are Logitech's names.
- Checked
- 2026-11-28
The tracked-hand shape drawn by the lab (the headset's own hand model)
partly verified- Source
- Meta Platform Technologies, LLC · source
- Publication
- delivered by the headset through the Meta XR Core SDK
- Licence
- Meta Platform Technologies SDK License Agreement (effective 25 October 2022)
- Attribution
- None stated.
- Changed
- No. The lab draws the shape the headset supplies, moved by the tracked joints.
- Used in
- film, where a mixed-reality shot shows the drawn hand; gallery, only if such a headset picture is chosen
- Notes
- The licence was read. Its section 1.1.3 lets an application display Meta's content to its users through the SDK, and section 1.2 names promoting your application as one purpose of the licence. It does not mention screenshots or film. NOT CONFIRMED with Meta.
- Checked
- 2026-11-28
The asset pack 'Vast Outer Space', present in the lab's project folder
verified- Source
- third party
- Licence
- Not looked up: the pack is not used.
- Used in
- not used
- Notes
- None of the pack's 292 asset files is referenced by the lab's main scene, by anything under Assets/TrilokaXR (which includes the filming scene) or by the lab's resources folder, so it is not on screen in the lab, the film or the gallery. Its folder is not part of the lab's commits. Open Brush's own bundled third-party code was not audited item by item; it ships with Open Brush.
- Checked
- 2026-11-28
Fonts
Typefaces of the page: Fraunces and Inter
verified- Source
- The Fraunces Project Authors; The Inter Project Authors · source
- Licence
- SIL Open Font License 1.1
- Attribution
- None for use on a web page.
- Changed
- No.
- Used in
- this page
- Notes
- Loaded from Google Fonts by the visitor's browser.
- Checked
- 2026-11-28
Your own work
The Open Brush artwork: sketch of 26 November 2026 (74 strokes) and every picture of it
your decision- Source
- Vaidehi Bhargava
- Licence
- © Vaidehi Bhargava 2026. Terms are yours to set.
- Attribution
- As you decide.
- Changed
- Painted over models derived from ISLES-2022 (CC BY 4.0) coloured with Neurosynth-derived values, so pictures that show those models also carry those two attributions.
- Used in
- film; gallery
- Notes
- Kept apart from the third-party scientific data and software above.
The film 'Spatial Brain XR Lab' and the mixed-reality recordings
your decision- Source
- Vaidehi Bhargava; Triloka XR
- Licence
- © Vaidehi Bhargava 2026. Terms are yours to set.
- Attribution
- As you decide.
- Used in
- this page
- Notes
- The recordings show you. The end card credits ISLES 2022, Neurosynth, SynthSeg and Open Brush.
The application's and the lab's own code, the page, and the records
your decision- Source
- Vaidehi Bhargava; Triloka XR
- Licence
- Unpublished; private repositories. Terms are yours to set.
- Used in
- application; XR lab; this page
- Notes
- AI-assisted; independent expert review pending. The hosted copy of the application makes its browser code readable to visitors.
Missing or unverified · 16
- Licences: Neurosynth association-test maps: reward, fear, motor, arousal, salience, movement, actionNOT CONFIRMED: whether the images served by neurosynth.org fall under the database's ODbL, and whether a per-structure table of values counts as a 'derivative database' that must itself be offered under the ODbL. Ask the Neurosynth maintainers or take advice before publication.
- Licences: MNI152NLin6Asym template brain (TemplateFlow copy), 1 mm T1-weightedNOT CONFIRMED: which terms cover the exact file used. The MNI page is for the symmetric model; TemplateFlow's file is FSL's asymmetric version. FSL's licence page (a non-commercial software licence) does not mention the MNI152 templates. It affects the pipeline, not what is displayed.
- Licences: Open Brush (the XR lab's base, version 2.32; the artwork's tool, version 2.31), including its brushes'Tilt Brush' is a Google trademark and must not be used as the name of a derived app. Seven gallery pictures carry the Open Brush logo that the program stamps on its snapshots: whether the logo may appear in published pictures was NOT checked. No separate licence for the brush shaders and textures was found in the repository; they were taken to be covered by the repository licence, which was NOT confirmed with the maintainers.
- Licences: Python libraries of the pipeline: nibabel, NumPy, SciPy, scikit-image, trimesh, fast-simplification, Pillow, FlaskNot redistributed. For NumPy, nibabel and Pillow the licence files were fetched but the licence type was not classified here.
- Licences: Logitech MX Ink pen model (logitech_vr_stylus_v1.0.fbx; seen in the film's stroke-replay shots)NOT CONFIRMED: the terms for showing the model in published film and pictures. No licence file sits in its folder in Open Brush; the MIT file in the neighbouring LogiPen folder belongs to a different, older Logitech pen. The repository behind Logitech's developer page is not public. 'MX Ink' and 'Logitech' are Logitech's names.
- Licences: The tracked-hand shape drawn by the lab (the headset's own hand model)The licence was read. Its section 1.1.3 lets an application display Meta's content to its users through the SDK, and section 1.2 names promoting your application as one purpose of the licence. It does not mention screenshots or film. NOT CONFIRMED with Meta.
- Provenance, step 2: Source scans and expert lesion annotationWhether the dataset's conversion from the scanner format mirrored any image at voxel level cannot be excluded from the file headers alone (the headers agree with the scanner's record to 0.0 degrees).
- Provenance, step 3: Automated anatomical segmentationThe effect of the compatibility patch on SynthSeg's output was not compared against an unpatched run.
- Provenance, step 5: Conversion into 3D anatomical modelsThe smoothing changes the surfaces slightly: the lesion mesh encloses 5.18 ml against 5.82 ml in the mask. No tolerance for this has been set or reviewed.
- Provenance, step 6: Functional reference-map sourcesWhich version of the Neurosynth database the website's maps come from: neurosynth.org does not state it.
- Provenance, step 7: Structure-level map sampling and anatomical overlapThe licence of the template brain (see the licence register).
- Provenance, step 10: Unity recreation and filmNo independent viewer has checked the film against its sources. Its pacing and joins were checked only by its maker, on frames.
- CitationsThe ISLES-2022 page on Zenodo asks for two works to be cited. The film's end card and the desktop study application's own source list name only the 2022 paper; the 2025 paper (de la Rosa et al., Nature Communications) is cited on this page only.
- CitationsThe bibliographic records of all cited papers were re-checked on 2026-11-28. The short literature summaries inside the desktop study application were last compared with the papers' abstracts on 2026-11-08 and 2026-11-11, and have not been reviewed by a specialist.
- CitationsUmeyama 1991 is cited for the alignment method. Its bibliographic record was checked; the paper itself was not read in this project.
- ReviewNo independent scientific or clinical review has taken place.
07Research bibliography and critical appraisalA continuing literature review.
In preparation. Initial version due 15 December 2026.
08Future research updatesDated notes on how the project develops.
In preparation.
09Scientific collaborationFor neurologists, neuroscientists and clinicians.
In preparation.